Home / Products / Mining Rack PDU 24-Outlet GB, 3-Phase 63 A
Mining Rack PDU 24-Outlet GB, 3-Phase 63 A
Mining PDU

Mining Rack PDU 24-Outlet GB, 3-Phase 63 A

Quick AnswerMining Rack PDU 24-Outlet GB, 3-Phase 63 A — an IDCPDU Mining PDU for mining farms and hash centres.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. 24 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  5. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.
  6. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.
  7. ⁦7–15⁩ working days after drawing approval — The clock starts when the drawing is signed off, and 30-minute proposals / 1-hour quotations come before that.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Twenty-four GB three-pin outlets down one 1269 mm body
  • Three-phase 63 A input through a 3-pole breaker
  • For Chinese-plug miners on a shared row feed
  • Domestic mining racks are built around the GB three-pin plug, and imported IEC strips force an adapter onto every machine. This strip carries twenty-four GB outlets along a 1269 mm body, fed from one three-phase 63 A terminal block through a 3-pole breaker that isolates all three phases together. The 65 × 83 mm body clears the rear channel of a 42U cabinet, and the outlets are spread over L1, L2 and L3 so a single-phase load does not sit on one phase. Cable entry works from the top or the bottom, which matters when a row is fed from overhead tray in one aisle and floor boxes in the next.

Frequently Asked Questions

What is the body dimensions (W×H) of Mining Rack PDU 24-Outlet GB, 3-Phase 63 A?

65 × 83 mm

What input connection does the Mining Rack PDU 24-Outlet GB, 3-Phase 63 A use?

OT terminal junction box

What is the input voltage of Mining Rack PDU 24-Outlet GB, 3-Phase 63 A?

380 V AC three-phase (⁦⁦220–250⁩⁩ V phase to neutral), 50/60 Hz

What is the max input current of Mining Rack PDU 24-Outlet GB, 3-Phase 63 A?

63 A per phase

What is the certification of Mining Rack PDU 24-Outlet GB, 3-Phase 63 A?

CE / EMC; built under ISO 9001