Home / Products / Dual-Rail Blind-Mate Manifold for In-Rack Liquid Cooling
Dual-Rail Blind-Mate Manifold for In-Rack Liquid Cooling
Manifold

Dual-Rail Blind-Mate Manifold for In-Rack Liquid Cooling

Quick AnswerDual-Rail Blind-Mate Manifold for In-Rack Liquid Cooling — an IDCPDU Manifold for liquid-cooling loops.
  1. Blind-mate coupling as the tray slides in — The connection closes on insertion, so a node is swapped without reaching behind the rack to seat hoses by hand.
  2. Self-closing, drip-free couplings — Both sides seal on disconnect, so a cold-plate swap leaves no coolant on the floor and no air in the loop.
  3. Two rails welded, then machined as one — Supply and return spacing is fixed by machining, not by assembly tolerance — blind-mate alignment does not drift after a few tray swaps.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Two parallel rails welded into one header for blind-mate docking
  • Single-rail version for hand-inserted push-in couplings
  • Automatic air vent, online service without draining the loop
  • In a blind-mate rack the mating half of the coupling sits on the server tray. The tray slides in, the couplings close by themselves and supply and return connect in one movement, so no one has to reach behind the rack with a hand.
  • The two rails are welded to each other and machined as one part, so the branch spacing on the supply side matches the return side and the tray engages on the first push instead of being wiggled into place.
  • Supply and return carry colour rings, an automatic vent releases trapped gas after filling, and one circuit can be isolated for service while the rest of the loop keeps running. The header distributes coolant between the liquid-cooled equipment inside the cabinet.
  • It mounts inside a 19-inch cold-plate rack, between the CDU feed and the cold plates. Length, branch count and branch spacing follow the rack layout, and where trays are connected by hand the same header is built in a single-rail version.

Frequently Asked Questions

Are you a direct manufacturer or a trading company?

IDCPDU is a direct manufacturer. We run our own factory and international sales department, with two casting foundries, one CNC machining factory and an in-house testing lab, so we produce and sell by ourselves.

What products does IDCPDU offer?

We focus on PDU, intelligent PDU, metered PDU, switched PDU, mining PDU, ATS, server rack cabinets and new energy vehicle charging boxes and distribution units.

What applications are your products used for?

Our products are mainly used in large data centers, intelligent power distribution systems and new energy charging piles.

Can you produce customized products?

Yes. Most of our orders are customized products built to the customer's drawings or samples, supported by our own R&D team.

Related Products

← Back to Products