Home / Products / 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical
26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical
Switched PDU

26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical

Quick Answer26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. 26 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  6. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  7. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Twenty-six C13 and C19 outlets in one 1.5U strip
  • Dense outlet count for networks, labs and broadcast racks
  • Per-outlet switching, metering and event logging
  • Twenty-six outlets in one strip solve the rack that is dense in devices but light in current: a lab bench of small servers, a broadcast rack of encoders and monitors, or a network rack of switches, routers and media converters. Every outlet switches and meters separately, and the event log records which outlet changed state and when, which is exactly what is needed when someone asks why a device rebooted at 03:00. The 1.5U body keeps the strip inside the rear channel without eating cable space.

Frequently Asked Questions

What is the input connection of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

Hard-wired terminal block, 5-wire

What is the input voltage of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

16 A (32 A version to order)

What is the rated power of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 26-Outlet C13 C19 Switched Rack PDU, 1.5U Vertical?

CE / EMC / RoHS; built under ISO 9001

Related Products