Home / Products / 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD
22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD
Metered PDU

22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD

Quick Answer22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  3. 22 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 22-outlet metered strip for taller cabinets in a 19-inch rack
  • Two extra outlets over the 20-way model cover switch and storage pairs
  • Hot-swap meter, RS485 Modbus-RTU and 3-lamp surge protection
  • Twenty-two outlets suit a 47U cabinet where each 1U server pair needs its own outlet and the two spare positions go to top-of-rack switches. Surge protection is three-lamp, so phase, neutral and earth status are visible individually. The meter bay swaps without shutdown and reports total current, voltage, power and energy over RS485.

Frequently Asked Questions

What input connection does the 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD use?

Hard-wired terminal block

What is the input voltage of 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

16 A (32 A version to order)

What is the rated power of 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

RS485 Modbus-RTU

What is the certification of 22-Outlet C13/C19 Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

CE / EMC / RoHS; built under ISO 9001