20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U
Switched PDU

20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U

Quick Answer20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. 20 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Field-standard input plug — Terminated with the connector electricians on site already stock, so commissioning does not wait for an adapter.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Twenty mixed C13 and C19 outlets on a 32 A cord set
  • Per-outlet switching and metering in a 1.5U body
  • Corded entry so the strip can be moved without an electrician
  • Twenty outlets in a 1391 mm body give a mid-density rack a socket for every device without doubling up on extension leads: C19 positions for switches, storage controllers and UPS-fed gear, C13 positions for servers and 1U appliances. Every outlet switches and meters individually, so a failed node is rebooted from the console while its neighbours carry on. Because the input is a 32 A cord set rather than a fixed terminal, the strip can be swapped or moved between racks without opening a panel.

Frequently Asked Questions

What is the input connection of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

2 m cord with 32 A industrial plug

What is the input voltage of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

32 A

What is the rated power of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

8 kW at 250 V

What is the monitoring interface of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 20-Outlet C13 C19 Switched Rack PDU, 32 A, 1.5U?

CE / EMC / RoHS; built under ISO 9001