Home / Products / 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD
18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD
Metered PDU

18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD

Quick Answer18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  3. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  4. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  5. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  6. Anodised aluminium body — Lighter than a steel shell and it sheds heat instead of trapping it; there is no paint layer to chip during installation.
  7. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Horizontal 1U metered strip with 18 German Schuko outlets
  • Covers mixed IT loads that ship with Schuko cords, from switches to lab gear
  • Hot-swap meter, RS485 Modbus-RTU and monitored surge protection
  • Schuko (Type F) is the plug used by European office and lab equipment that is not sold with an IEC inlet, so a rack shared by network gear, test instruments and workstations can be fed from one strip. Eighteen outlets at ⁦220–250⁩ V with hydraulic magnetic protection, and the meter reports total current, voltage, power and energy over RS485. Surge protection is monitored, so a spent module is reported rather than silently ignored.

Frequently Asked Questions

What input connection does the 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD use?

Hard-wired terminal block

What is the input voltage of 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD?

16 A (32 A version to order)

What is the rated power of 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD?

RS485 Modbus-RTU

What is the certification of 18-Outlet German Schuko Metered Rack PDU, 1U, Hot-Swap Meter, RS485, SPD?

CE / EMC / RoHS; built under ISO 9001