Home / Products / 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical
16-Outlet South Africa Switched Rack PDU, 1.5U Vertical
Switched PDU

16-Outlet South Africa Switched Rack PDU, 1.5U Vertical

Quick Answer16-Outlet South Africa Switched Rack PDU, 1.5U Vertical — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  6. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  7. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Sixteen South African SANS 164 outlets, large and small patterns
  • Two breakered groups of eight, each outlet switched and metered
  • Built for South African racks that cannot use IEC strips
  • South African racks mix the large three-pin SANS ⁦164-1⁩ outlet with the smaller SANS 164 pattern, and imported IEC strips force every device onto an adapter. This strip carries sixteen SANS 164 outlets in two groups of eight, each group behind its own 1-pole 32 A hydraulic-magnetic breaker, with per-outlet switching and metering. The 1.5U body runs the full height of a 42U cabinet, so a socket sits within reach of every shelf.

Frequently Asked Questions

What is the input connection of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

16 A (32 A version to order)

What is the rated power of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet South Africa Switched Rack PDU, 1.5U Vertical?

CE / EMC / RoHS; built under ISO 9001