Home / Products / 16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U
16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U
Basic PDU

16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U

Quick Answer16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  4. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 16 Chinese-standard sockets on a 0U vertical strip
  • 63 A input split across main and branch breakers
  • 1398 mm mounting length for 42U cabinets
  • The 125 × 62 mm body mounts in the rear rail channel of a 42U cabinet and leaves the side cable managers free. Sockets are the GB three-pin type with anti-drop latch, so plugs cannot work loose under vibration.
  • Power enters through an OT terminal junction box — no plug to be pulled out by accident — and is distributed from a tinned copper busbar. The main breaker isolates the whole strip, while branch breakers protect each group of outlets.
  • Used in Chinese data centres, telecom base stations and factory IT rooms where GB sockets, not IEC C13, are the installed standard.
  • Other outlet counts, branch groupings and cable lengths are made to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

What is the body dimensions (W×H) of 16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U?

125 × 62 mm

What is the max input current of 16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U?

63 A

What is the input voltage of 16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What input connection does the 16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U use?

OT terminal junction box

What is the certification of 16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U?

CE / EMC / RoHS; built under ISO 9001