Home / Products / 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A
16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A
Switched PDU

16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A

Quick Answer16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  4. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  5. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  6. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.
  7. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Sixteen C19 outlets on a single 63 A feed, in a 2U box
  • Per-outlet switching and metering for sixteen C20-corded loads
  • Top or bottom cable entry, left or right power routing
  • Sixteen C19 outlets in one 2U chassis replace two vertical strips when a rack holds a dense block of blade chassis, storage shelves or network cores — every one of them arrives with a C20 cord, so C13 positions would sit unused. Each outlet switches and meters separately, letting you stage power-up of sixteen devices after a room-wide outage. The 63 A inlet takes a hard-wired five-wire feed from the panel, and the front LCD shows current, voltage, power and energy without opening the door.

Frequently Asked Questions

What is the input connection of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

63 A

What is the rated power of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

Up to 15 kW at 250 V

What is the monitoring interface of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet C19 Switched Rack PDU, 2U Horizontal, 63 A?

CE / EMC / RoHS; built under ISO 9001