Home / Products / 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A
16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A
Switched PDU

16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A

Quick Answer16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  6. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  7. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Mixed strip for racks that hold both IEC and NEMA loads
  • Eight NEMA ⁦5-15⁩ and eight IEC C13 / C19 outlets, 63 A feed
  • Per-outlet switching for remote reboot of mixed equipment
  • North American racks rarely hold one plug type. A single strip here carries eight NEMA ⁦5-15⁩ outlets for 1U switches, KVMs and appliances, plus eight IEC positions for servers and storage that arrive with C13 or C20 cords. Every outlet switches and meters on its own, so a hung appliance can be rebooted remotely without touching the servers behind it. The 63 A five-wire inlet feeds the whole strip, and the vertical 1358 mm body leaves the rear of a 42U rack clear for cabling.

Frequently Asked Questions

What is the input connection of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

63 A

What is the rated power of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

Up to 15 kW at 250 V

What is the monitoring interface of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet C13 C19 US Switched Rack PDU, Vertical, 63 A?

CE / EMC / RoHS; built under ISO 9001