Home / Products / 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical
16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical
Switched PDU

16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical

Quick Answer16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Sixteen-outlet switched strip with per-outlet remote control
  • Twelve C13 and four C19 outlets on two separately breakered groups
  • LCD metering with SNMP, Modbus TCP and web access
  • Each group carries six C13 and two C19 outlets behind its own 1-pole hydraulic-magnetic breaker, so a hung server can be isolated and power-cycled from the browser without dropping the rest of the rack. Per-outlet relays allow sequential start with a 1 to 250 second interval between outlets, which keeps inrush from tripping the upstream breaker when a full rack comes back after a maintenance window. Current, voltage, power and energy are shown on the LCD and published over SNMP v1/v2/v3 or Modbus TCP.

Frequently Asked Questions

What is the input connection of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

16 A (32 A version to order)

What is the rated power of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet C13 C19 Switched Rack PDU, TCP/IP, 1.5U Vertical?

CE / EMC / RoHS; built under ISO 9001