Home / Products / 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U
14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U
Basic PDU

14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U

Quick Answer14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  4. Master switch on the body — Field maintenance starts with one visible break, which is exactly what a lockout/tagout procedure asks for.
  5. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Vertical 0U strip for 19-inch server racks
  • 14 Swiss SEV 1011 (Type J) outlets, 10 A each
  • Master switch for one-touch isolation during service
  • The 505 mm mounting length suits 22U to 27U cabinets, wall boxes and network enclosures; the 120 × 45 mm extruded body keeps the rear cable path clear and the strip is fixed with the supplied M6 screws on ⁦465–505⁩ mm centres.
  • Outlets are fed from a single copper busbar with resistance-welded taps instead of daisy-chained leads, so the last outlet sees practically the same voltage as the first when all 14 are loaded.
  • Typical installations: Swiss and Liechtenstein IT rooms, branch offices and laboratory racks where IEC C13 is not the local socket standard.
  • Other socket combinations, cable lengths and plug types are built to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

What is the body dimensions (W×H) of 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U?

120 × 45 mm

What is the input voltage of 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U?

220 V AC, 50/60 Hz

What input connection does the 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U use?

Hard-wired terminal block

What is the certification of 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U?

CE / EMC; built under ISO 9001